2 Parameters
2.2 List of parameters
r0946[0...65534]
Fault code list / Fault code list
TM150, TM15DI_DO,
Can be changed: -
TM31
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Lists the fault codes stored in the drive unit.
The indices can only be accessed with a valid fault code.
Dependency:
The parameter assigned to the fault code is entered in r0951 under the same index.
r0947[0...63]

Fault number / Fault number

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S, DC_CTRL,
P-Group: Messages
DC_CTRL_R,
Not for motor type: -
DC_CTRL_R_S,
DC_CTRL_S
Min
-
Description:
This parameter is identical to r0945.
r0947[0...63]
Fault number / Fault number
TM150, TM15DI_DO,
Can be changed: -
TM31
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
This parameter is identical to r0945.
r0948[0...63]

Fault time received in milliseconds / t_fault recv ms

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S, DC_CTRL,
P-Group: Messages
DC_CTRL_R,
Not for motor type: -
DC_CTRL_R_S,
DC_CTRL_S
Min
- [ms]
Description:
Displays the system runtime in milliseconds when the fault occurred.
Dependency:
Refer to: r0945, r0947, r0949, r2109, r2114, r2130, r2133, r2136, r3115, r3120, r3122
Notice:
The time comprises r2130 (days) and r0948 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the fault buffer and the assignment of the indices is shown in r0945.
When the parameter is read via PROFIdrive, the TimeDifference data type applies.
r0948[0...63]
Fault time received in milliseconds / t_fault recv ms
TM150, TM15DI_DO,
Can be changed: -
TM31
Data type: Unsigned32
P-Group: Messages
Not for motor type: -
Min
- [ms]
Description:
Displays the system runtime in milliseconds when the fault occurred.
108
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [ms]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 8050, 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [ms]
Access level: 3
Func. diagram: 8050, 8060
Unit selection: -
Expert list: 1
Factory setting
- [ms]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents