Co/Bo: Field Auto-Reversing Stage State / Field Stage State; Co/Bo: Armature Current State / Ia State; Co/Bo: Field Current Setpoint Limiting State / If Lim State; Co/Bo: Field Reversal Contactor Signals / Field Rev Cont Sig - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r53191.0...2

CO/BO: Field auto-reversing stage state / Field stage state

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the state of the auto-reversing stage for field control.
Bit field:
Bit
00
01
02
r53192.0

CO/BO: Armature current state / Ia state

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the state of the armature current.
Bit field:
Bit
00
r53193.0...3

CO/BO: Field current setpoint limiting state / If lim state

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Control word for field current setpoint limiting.
Bit field:
Bit
00
01
02
03
r53195.0...2

CO/BO: Field reversal contactor signals / Field rev cont sig

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Control word to control the field contactors for field reversal.
Bit field:
Bit
00
01
02
Dependency:
Refer to: p50092, p50580, p50581, p50583
640
Signal name
Alpha G limit reached
Alpha W limit reached
Alpha G/Alpha W limit reached
Signal name
Armature current not pulsating
Signal name
Positive field current setpoint limit reached
Negative field current setpoint limit reached Yes
Standstill field switched in
Field current setpoint withdrawn
Signal name
Field direction positive
Field direction negative
Invert speed actual value
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
Yes
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6910, 6915
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
Access level: 2
Func. diagram: 6850
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
Access level: 2
Func. diagram: 6900, 6905
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
Access level: 2
Func. diagram: 6920
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF
No
SINAMICS DCM
FP
6910,
6915
6910,
6915
6915
FP
6850
FP
-
-
-
-
FP
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents