2 Parameters
2.2 List of parameters
r52311[0...1]
CO: Current actual value of the parallel power units / Ia par_power_unit
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the current actual values of the cabinet devices with power units connected in
parallel.
Only active for 6RM80 with options Z04, Z05, Z07, Z13 and Z15
Index:
[0] = Power unit 1
[1] = Power unit 2
r52312[0...1]
CO: I2T thyristor temperature rise of the parallel power units / I2T par_power unit
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the thyristor temperature rise of the cabinet devices with power units connected in
parallel.
Index:
[0] = Power unit 1
[1] = Power unit 2
Note:
This parameter is only active for 6RM80 devices with options Z04, Z05, Z07, Z13 and Z15.
r52316
CO: Field line frequency / Field f_line
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the field line frequency.
The value is a percentage of 50 Hz.
r52320
CO: Armature current control counter EMF ratio / V_counter_ratio
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output of the counter EMF ratio EMF/V_line.
Dependency:
Refer to: r52122, r52305
596
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 8042
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 8042
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6952
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6855
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM