2 Parameters
2.2 List of parameters
p0922
IF1 PROFIdrive PZD telegram selection / IF1 PZD telegr
DC_CTRL,
Can be changed: C2(1), T
DC_CTRL_R,
Data type: Unsigned16
DC_CTRL_R_S,
P-Group: Communications
DC_CTRL_S
Not for motor type: -
Min
1
Description:
Sets the send and receive telegram.
Value:
1:
3:
4:
20:
220:
352:
999:
Note:
For p0922 = 100 ... 199, p2038 is automatically set to 1 and p2038 can no longer be changed. This means that for
these telegrams, the "SIMODRIVE 611 universal" interface mode is set and cannot be changed.
If a value is not equal to 999, a telegram is set and the automatically set interconnections in the telegram are
inhibited.
The inhibited interconnections can only be changed again after setting value 999.
r0924[0...1]

ZSW bit pulses enabled / ZSW pulse enab

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned16
DC_CTRL_R_S,
P-Group: Communications
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the position of the "Pulses enabled" status signal in the PROFIdrive telegram.
Index:
[0] = Signal number
[1] = Bit position
r0944

CO: Counter for fault buffer changes / Fault buff change

All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays fault buffer changes. This counter is incremented every time the fault buffer changes.
Recommendation:
Used to check whether the fault buffer has been read out consistently.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109
r0945[0...63]

Fault code / Fault code

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S, DC_CTRL,
P-Group: Messages
DC_CTRL_R,
Not for motor type: -
DC_CTRL_R_S,
DC_CTRL_S
Min
-
Description:
Displays the numbers of faults that have occurred.
Dependency:
Refer to: r0947, r0948, r0949, r2109, r2130, r2133, r2136, r3120, r3122
Notice:
The properties of the fault buffer should be taken from the corresponding product documentation.
106
Standard telegram 1, PZD-2/2
Standard telegram 3, PZD-5/9
Standard telegram 4, PZD-6/14
Standard telegram 20, PZD-2/6
SIEMENS telegram 220, PZD-10/10
SIEMENS telegram 352, PZD-6/6
Free telegram configuration with BICO
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
999
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 1520, 2420
Unit selection: -
Expert list: 1
Factory setting
999
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM