Cud Analog Input 2 Offset / Cud Ai 2 Offs; Cud Analog Input 2 Signal Processing / Cud Ai 2 Sig Proc; Bi: Cud Analog Input 2 Inversion / Cud Ai 2 Inv; Cud Analog Input 2 Smoothing Time Constant / Cud Ai 2 T - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p50722

CUD analog input 2 offset / CUD AI 2 offs

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the offset for analog input 2 (X177.29/30) on the CUD.
p50723

CUD analog input 2 signal processing / CUD AI 2 sig proc

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the signal processing mode for analog input 2 (X177.29/30) on the CUD.
Value:
0:
1:
2:
3:
p50724

BI: CUD analog input 2 inversion / CUD AI 2 inv

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for inverting the signal from analog input 2 (X177.29/30) on the CUD.
1 signal: Inversion
0 signal: No inversion
p50725

CUD analog input 2 smoothing time constant / CUD AI 2 T

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the time constant for smoothing the signal from analog input 2 (X177.29/30) on the CUD.
p50726
BI: CUD analog input 2 signal source for enable / CUD AI 2 ena sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for enabling analog input 2 (X177.29/30) on the CUD.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal not controlled
Signal absolute value generation
Signal inverted
Signal absolute value generation inverted
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
1
505

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents