2 Parameters
2.2 List of parameters
p50136[0...n]

Field current for motor flux 80 % / I_field flux 80%

DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 80 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50135 and less than p50137 can be set.
p50137[0...n]

Field current for motor flux 85 % / I_field flux 85%

DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 85 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50136 and less than p50138 can be set.
p50138[0...n]

Field current for motor flux 90 % / I_field flux 90%

DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 90 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50137 and less than p50139 can be set.
p50139[0...n]

Field current for motor flux 95% / I_field flux 95%

DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 95%.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50138 can be set.
408
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
64.9 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
71.8 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
79.8 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
89.1 [%]