2 Parameters
2.2 List of parameters
p51814[0...15]
CI: Parallel interface master transmit data / PI master tr data
DC_CTRL
Can be changed: U, T
Data type: Unsigned32 / Integer16
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal sources for transmit data when operating the device as a master on the parallel interface.
Index:
[0] = Word 1
[1] = Word 2
[2] = Word 3
[3] = Word 4
[4] = Word 5
[5] = Word 6
[6] = Word 7
[7] = Word 8
[8] = Word 9
[9] = Word 10
[10] = Word 11
[11] = Word 12
[12] = Word 13
[13] = Word 14
[14] = Word 15
[15] = Word 16
Note:
This parameter is used to define the transmit data and its position in the transmit telegram.
[0]: Word 1 in the telegram
...
[4]: Word 5 in the telegram
[5]: Word 1 in the telegram
...
[9]: Word 5 in the telegram
...
p51815
Parallel interface number of devices / Par_IF device qty
DC_CTRL
Can be changed: T
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
1
Description:
Sets the number of CUDs, which communicate with one another via the parallel switching interface.
This setting is intended so that every device connected to the parallel switching interface can monitor whether all
devices are active and/or available.
Each of the devices connected to the parallel switching interface continually monitors whether all of the devices
regularly send telegrams.
"Device connected to the parallel switching interface" is every CUD, at which p51800 > 0 .
"Regularly sending telegrams" means that the time between two send telegrams from the same device must be less
than 100 ms.
Note:
- If the number set here is less than the actual number of devices connected to the parallel switching interface, then
failure of some of the devices is ignored.
- A setting of 1 means that the monitoring is inactive.
550
Calculated: -
Dyn. index: -
Unit group: -
Scaling: 4000H
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 9355
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 9350
Unit selection: -
Expert list: 1
Factory setting
1