p50794[0...4]

CI: P2P IF transmit data signal source / P2P tr data sig s

DC_CTRL
Can be changed: U, T
Data type: Unsigned32 / Integer16
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the data to be transmitted on the peer-to-peer interface (P2P IF).
The transmit data is displayed in r50813[0 to 4].
Index:
[0] = Word 1
[1] = Word 2
[2] = Word 3
[3] = Word 4
[4] = Word 5
Dependency:
Refer to: r50813
p50795

P2P/CCP bus terminator / P2P/CCP bus term

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the bus terminator for the peer-to-peer interface and the interface to the SIMOREG CCP.
Value:
0:
1:
Note:
CCP: Converter Commutation Protector
P2P: Peer-to-Peer interface
p50797

P2P IF telegram monitoring time / P2P t_telegr mon

DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.000 [s]
Description:
Sets the telegram monitoring time for the peer-to-peer interface (P2P IF).
The time set is only effective in "Peer-to-peer interface" operating mode (p50790 = 5).
p50797 = 0:
Monitoring is de-activated.
p50797 > 0:
Monitoring is activated.
As well as one valid telegram being received, the next valid telegram must be received within the set time. Otherwise,
fault F60012 is triggered.
Dependency:
Refer to: F60012
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
9600 baud
19200 baud
38400 baud
56700 baud
93750 baud
187500 baud
OFF
ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: 4000H
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65.000 [s]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 9300
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 6970, 9300
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 9300
Unit selection: -
Expert list: 1
Factory setting
0.000 [s]
519