If1 Profidrive Diagnostics Pzd Send Double Word / If1 Diag Send Dw - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

[54] = PZD 55 + 56
[55] = PZD 56 + 57
[56] = PZD 57 + 58
[57] = PZD 58 + 59
[58] = PZD 59 + 60
[59] = PZD 60 + 61
[60] = PZD 61 + 62
[61] = PZD 62 + 63
[62] = PZD 63 + 64
Dependency:
Refer to: p2051
Notice:
A BICO interconnection for a single PZD can only take place either on p2051 or p2061.
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
IF1: Interface 1
r2063[0...62]

IF1 PROFIdrive diagnostics PZD send double word / IF1 diag send DW

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Communications
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the PZD (actual values) with double word format sent to the fieldbus controller.
Index:
[0] = PZD 1 + 2
[1] = PZD 2 + 3
[2] = PZD 3 + 4
[3] = PZD 4 + 5
[4] = PZD 5 + 6
[5] = PZD 6 + 7
[6] = PZD 7 + 8
[7] = PZD 8 + 9
[8] = PZD 9 + 10
[9] = PZD 10 + 11
[10] = PZD 11 + 12
[11] = PZD 12 + 13
[12] = PZD 13 + 14
[13] = PZD 14 + 15
[14] = PZD 15 + 16
[15] = PZD 16 + 17
[16] = PZD 17 + 18
[17] = PZD 18 + 19
[18] = PZD 19 + 20
[19] = PZD 20 + 21
[20] = PZD 21 + 22
[21] = PZD 22 + 23
[22] = PZD 23 + 24
[23] = PZD 24 + 25
[24] = PZD 25 + 26
[25] = PZD 26 + 27
[26] = PZD 27 + 28
[27] = PZD 28 + 29
[28] = PZD 29 + 30
[29] = PZD 30 + 31
[30] = PZD 31 + 32
[31] = PZD 32 + 33
[32] = PZD 33 + 34
[33] = PZD 34 + 35
[34] = PZD 35 + 36
[35] = PZD 36 + 37
[36] = PZD 37 + 38
[37] = PZD 38 + 39
[38] = PZD 39 + 40
[39] = PZD 40 + 41
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2450, 2470
Unit selection: -
Expert list: 1
Factory setting
-
141

Hide quick links:

Advertisement

Table of Contents
loading