Ci: Acceleration Value For Inertia Compensation / Comp Inert Acc Val; Ci: Speed Controller Setpoint/Actual Value Difference Signal Source; Ci: Speed Controller Setpoint 1 Signal Source / N_Ctr Set 1 Sig S; Ci: Speed Controller Setpoint 2 Signal Source / N_Ctr Set 2 Sig S - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p50619

CI: Acceleration value for inertia compensation / Comp inert acc val

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the acceleration value for inertia compensation.
p50620
CI: Speed controller setpoint/actual value difference signal source / n_ctr set/ac sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the setpoint/actual value difference on the speed controller.
Dependency:
Refer to: r52164
Note:
The setpoint/actual value difference for the speed controller is available in r52164 for further interconnection.
p50621

CI: Speed controller setpoint 1 signal source / n_ctr set 1 sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for setpoint 1 on the speed controller.
Dependency:
Refer to: p50622, p50623, p50624, r52165
Note:
The setpoint/actual value difference (r52165) results from setpoint 1 and 2 (p50621, p50622) and actual value 1 and
2 (p50623, p50624).
p50622

CI: Speed controller setpoint 2 signal source / n_ctr set 2 sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for setpoint 2 on the speed controller.
Dependency:
Refer to: p50621, p50623, p50624, r52165
Note:
The setpoint/actual value difference (r52165) results from setpoint 1 and 2 (p50621, p50622) and actual value 1 and
2 (p50623, p50624).
p50623
CI: Signal source for speed controller actual value 1 / n_ctr act 1 sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for actual value 1 on the speed controller.
488
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 6820
Unit selection: -
Expert list: 1
Factory setting
52191[0]
Access level: 3
Func. diagram: 6815
Unit selection: -
Expert list: 1
Factory setting
52165[0]
Access level: 3
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
52176[0]
Access level: 3
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
52174[0]
Access level: 3
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
52179[0]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents