Nvram Data Backup/Import/Delete / Nvram Backup; Drive-Cliq Component Component Number / Dq Compo_No; Drive-Cliq Component Parameter Number / Dq Para_No - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p7775

NVRAM data backup/import/delete / NVRAM backup

CU_DC, CU_DC_R,
Can be changed: C1, U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to backup/import/delete NVRAM data.
NVRAM data are non-volatile data in the device (e.g. fault buffer).
For NVRAM data actions, the following data are excluded:
- Crash diagnostics
- CU operating hours counter
- CU temperature
- Safety logbook
Value:
0:
1:
2:
3:
10:
11:
12:
13:
14:
15:
16:
17:
Notice:
Re value = 2, 3:
These actions are only possible when pulses are inhibited.
Note:
After the action has been successfully completed, the parameter is automatically set to zero.
The actions importing and deleting NVRAM data immediately initiate a warm restart.
If the procedure was not successfully completed, then an appropriate fault value is displayed (p7775 >= 10).
p7820

DRIVE-CLiQ component component number / DQ compo_no

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the component number of the DRIVE-CLiQ component whose parameters are to be accessed.
Dependency:
Refer to: p7821, p7822, r7823
p7821

DRIVE-CLiQ component parameter number / DQ para_no

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter number to access a parameter of a DRIVE-CLiQ component.
Dependency:
Refer to: p7820, p7822, r7823
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Inactive
NVRAM data backup to memory card
Import NVRAM data from the memory card
Delete NVRAM data in the device
Error when clearing
Error when backing up, memory card not available
Error when backing up, insufficient memory space
Error when backing up
Error when importing, memory card not available
Error when importing, checksum error
Error when importing, no NVRAM data available
Error when importing
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
17
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
295