Ci: Emf/Ua External Signal Source / Emf/Ua Ext Sig S; Speed Controller Speed Actual Value Smoothing Time Constant; Band-Stop 1 Resonant Frequency / Band-St 1 F_N; Band-Stop 1 Quality / Band-St 1 Quality - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p50193

CI: EMF/Ua external signal source / EMF/Ua ext sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for EMF actual value or armature voltage actual value for armature current pre-control.
If p50162[D] = 2: Armature voltage actual value
If p50162[D] = 3: EMF actual value
p50200[0...n]
Speed controller speed actual value smoothing time constant / n_ctr n_act T
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the smoothing time constant for smoothing the speed actual value on the speed controller.
p50201[0...n]

Band-stop 1 resonant frequency / Band-st 1 f_n

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
1 [Hz]
Description:
Sets the resonant frequency for band-stop 1.
Dependency:
Refer to: p50202, p50628, r52177
p50202[0...n]

Band-stop 1 quality / Band-st 1 quality

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the quality for band-stop 1.
Value:
0:
1:
2:
3:
Dependency:
Refer to: p50201, p50628, r52177
p50203[0...n]
Band-stop 2 resonant frequency / Band-st 2 f_n
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
1 [Hz]
Description:
Sets the resonant frequency for band-stop 2.
420
Quality = 0.5
Quality = 1
Quality = 2
Quality = 3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
140 [Hz]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
140 [Hz]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 6852
Unit selection: -
Expert list: 1
Factory setting
52287[0]
Access level: 2
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
1 [Hz]
Access level: 2
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
1 [Hz]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading