2 Parameters
2.2 List of parameters
p50500[0...n]
CI: Torque limiting signal source for t_set in slave mode / T_set s mode sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the torque setpoint in slave mode.
Dependency:
Refer to: p50503
p50501[0...n]
CI: Torque limiting signal source for torque additional setpoint / T_lim add s sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the torque additional setpoint in torque limiting.
The value is injected in addition to friction and moment of inertia compensation.
p50502
CI: Speed controller additional setpoint signal source / Add set sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the additional setpoint of the speed controller.
This value is added to the speed controller's output value.
p50503[0...n]

Torque limiting t_set factor in slave mode / T_set fact sl mode

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-300.00 [%]
Description:
Sets the factor for the torque setpoint in slave mode.
Dependency:
Refer to: p50500
p50509
CI: Speed limiting controller signal source for speed actual value / n_lim n_act sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed actual value (n_act) on the speed limiting controller.
468
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
300.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6830
Unit selection: -
Expert list: 1
Factory setting
52170[0]
Access level: 2
Func. diagram: 6830
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 6815
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 6830
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 6835
Unit selection: -
Expert list: 1
Factory setting
52167[0]