Ci: Messages Polarity Speed Actual Value Signal Source; Ci: Signal Source For Armature Gating Unit Input / A G Unit In Sig S; Ci: Signal Source For Speed Limiting Controller Setpoint - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Dependency:
Refer to: p50596, r53025
p50598[0...n]
CI: Messages polarity speed actual value signal source / MsgPol n_act S_src
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the "Speed actual value polarity" message.
Dependency:
Refer to: p50372, r53025
p50600[0...4]

CI: Signal source for armature gating unit input / A g unit in sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the gating unit input on the armature circuit.
p50601[0...5]
CI: Signal source for speed limiting controller setpoint / n_lim set sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the setpoint on the armature current controller.
Notice:
Re index 5:
When entering a supplementary current setpoint via p50601[5] it is not permissible to use the current setpoint
integrator or the reduced gearbox load function. p50158 must be set = 0.000 s.
Possible effect if this is not observed:
Torque direction change will not be able to be completed. The drive remains in one torque direction.
Note:
[0 to 1] = Speed limiting controller
Sets the signal sources for the setpoint on the speed limiting controller. The two values are added together.
[2 to 3] = Current limitation
Sets the signal sources for the setpoint on the current controller (before current limitation). The two values are added
together.
[4 to 5] = Closed-loop current control
Sets the signal sources for the setpoint on the current controller (before the current controller). The two values are
added together. The absolute value is generated from the value in index 5.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8025
Unit selection: -
Expert list: 1
Factory setting
52179[0]
Access level: 3
Func. diagram: 6858, 6860
Unit selection: -
Expert list: 1
Factory setting
[0] 52102[0]
[1...4] 0
Access level: 3
Func. diagram: 6835, 6840,
6855
Unit selection: -
Expert list: 1
Factory setting
[0] 52141[0]
[1] 0
[2] 52134[0]
[3] 0
[4] 52125[0]
[5] 0