Bootloader Version / Bootloader Vers; Bios/Eeprom Data Version / Bios/Eeprom Vers; Drive Object Name / Do Name - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r0197[0...1]

Bootloader version / Bootloader vers

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Displays the bootloader version.
Index 0:
Displays the bootloader version.
Index 1:
Displays the bootloader version 3 (for CU320-2 and CU310-2)
Value 0 means that boot loader 3 is not available.
Dependency:
Refer to: r0018, r0148, r0158, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
r0198[0...2]

BIOS/EEPROM data version / BIOS/EEPROM vers

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Displays the BIOS and EEPROM data version.
r0198[0]: BIOS version
r0198[1]: EEPROM data version EEPROM 0
r0198[2]: EEPROM data version EEPROM 1
Dependency:
Refer to: r0018, r0148, r0158, r0197
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
p0199[0...24]

Drive object name / DO name

All objects
Can be changed: C1
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
0
Description:
Freely assignable name for a drive object.
In the commissioning software, this name cannot be entered using the expert list, but is specified in the configuration
assistant. The object name can be subsequently modified in the Project Navigator using standard Windows
resources.
Note:
The parameter is not influenced by setting the factory setting.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents