Oa Do-Specific Number / Oa Do Qty; Oa Do-Specific Identifier Total Length / Oa Do Id Tot_Lgth; Oa Do-Specific Guid Total Length / Oa Do Guid Length; Oa Do-Specific Identifier / Oa Do Ident - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Dependency:
Refer to: p4840, r4841
r4950

OA DO-specific number / OA DO qty

All objects
Can be changed: -
Data type: Unsigned16
P-Group: OEM range
Not for motor type: -
Min
0
Description:
Displays the number of OA applications installed on this drive object.
Dependency:
Refer to: r4951, r4952, r4955, p4956, r4957, r4958, r4959, r4960
Note:
DO: Drive Object
OA: Open Architecture (OA application)
r4951

OA DO-specific identifier total length / OA DO id tot_lgth

All objects
Can be changed: -
Data type: Unsigned16
P-Group: OEM range
Not for motor type: -
Min
0
Description:
Displays the total length of the identifiers of the OA applications installed on this drive object.
Dependency:
Refer to: r4950, r4952, r4955, p4956, r4957, r4958, r4959, r4960
Note:
The identifier of an OA application comprises a maximum of 8 characters plus separator.
r4952

OA DO-specific GUID total length / OA DO GUID length

All objects
Can be changed: -
Data type: Unsigned16
P-Group: OEM range
Not for motor type: -
Min
0
Description:
Displays the total length of the GUIDs of the OA applications installed on this drive object.
Dependency:
Refer to: r4950, r4951, r4955, p4956, r4957, r4958, r4959, r4960
Note:
The GUID of an OA application comprises 16 characters plus 1 character major information plus 1 character, minor
information.
GUID: Globally Unique IDentifier
r4955[0...n]

OA DO-specific identifier / OA DO ident

All objects
Can be changed: -
Data type: Unsigned8
P-Group: OEM range
Not for motor type: -
Min
-
Description:
Displays the identifier of the OA applications installed on this drive object.
r4955[0...8]: Identifier of OA application 1
r4955[9...17]: Identifier of OA applications 2, ...
Dependency:
Refer to: r4950, r4951, r4952, p4956, r4957, r4958, r4959, r4960
Notice:
If there is no OA application, then it is not possible to access an index.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
144
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
288
Calculated: -
Dyn. index: r4951
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
283

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents