p0009 = 2: Defines the drive type / function module
In this state, the drive object types and/or the function modules can be changed or selected for the individual drive
objects. To do this, the drive object type can be set using p0107[0...15] and the function can be set using
p0108[0...15] (refer to p0101[0...15]).
p0009 = 3: Drive basic configuration
In this state, after the device has been commissioned for the first time, basic changes can be made for the individual
drive objects (e.g. sampling times in p0111, p0112, p0115 and the number of data sets in p0120, p0130, p0140,
p0170, p0180).
p0009 = 4: Data set basic configuration
In this state, after the device has been commissioned for the first time, for the individual drive objects changes can be
made regarding the assignment of the components (p0121, p0131, p0141, p0151, p0161) to the individual data sets
and the assignment of the power unit, motor and encoder to the drive data sets (p0185, ...).
p0009 = 29: Device download
If a download is made using the commissioning software, the device is automatically brought into this state. After the
download has been completed, p0009 is automatically set to 0 (ready). It is not possible to manually set p0009 to this
value.
p0009 = 30: Parameter reset
In order to bring the complete unit into the "first commissioning" state or to load the parameters saved using p0977, to
start, p0009 must be set to this value. p0976 can then be changed to the required value.
p0009 = 50: OA application configuration
In this state, after the device has been commissioned for the first time, changes can be made for the individual drive
objects regarding the activity (p4956) of the OA applications.
p0009 = 55: OA application installation
OA applications can be installed and/or uninstalled in this state.
p0010

Drive commissioning parameter filter / Drv comm. par_filt

DC_CTRL,
Can be changed: C2(1), T
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: -
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Sets the parameter filter to commission a drive.
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
Value:
0:
1:
4:
15:
29:
30:
Note:
The drive can only be powered up outside the drive commissioning (drive enable). To realize this, this parameter
must be set to 0.
By setting p3900 to a value other than 0, the quick commissioning is completed, and this parameter is automatically
reset to 0.
p0010

TM150 commissioning parameter filter / TM150 com par_filt

TM150
Can be changed: C2(1), T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter filter for commissioning a Terminal Module 150 (TM150).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Ready
Quick commissioning
Encoder commissioning
Data sets
Only Siemens int
Reserved
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
30
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
30
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
35