2 Parameters
2.2 List of parameters
Value:
0:
29:
30:
Dependency:
Refer to: p0970
Note:
Only the following values are possible: p0010 = 0, 30
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
p0010
TM15DI/DO commissioning the parameterizing filter / TM15D com par_filt
TM15DI_DO
Can be changed: C2(1), T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter filter for commissioning a Terminal Module 15 (TM15).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
29:
30:
Dependency:
Refer to: p0970
Note:
Only the following values are possible: p0010 = 0, 30
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
p0010
TM31 commissioning parameter filter / TM31 comm par_filt
TM31
Can be changed: C2(1), T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter filter for commissioning a Terminal Module 31 (TM31).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
29:
30:
Dependency:
Refer to: p0970
Note:
Only the following values are possible: p0010 = 0, 30
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
p0011
BOP password entry (p0013) / BOP passw ent p13
CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: Functions
Not for motor type: -
Min
0
Description:
Sets the password for the Basic Operator Panel (BOP).
Dependency:
Refer to: p0012, p0013
36
Ready
Only Siemens int
Parameter reset
Ready
Only Siemens int
Parameter reset
Ready
Only Siemens int
Parameter reset
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
30
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
30
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS DCM