2 Parameters
2.2 List of parameters
r52289

CO: EMF controller setpoint absolute value / EMF ctr set abs

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the absolute value of the setpoint on the EMF controller.
Dependency:
Refer to: r50039, p50100, p50101, p50110
Note:
A value of 100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi.
r52290
CO: Closed-loop field current control motor flux output / If ctr motor flux
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of the motor flux in the case of closed-loop field current control.
The value is a percentage of p50102.
r52291

CO: Armature voltage actual value absolute value / Ua act abs

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the actual value of the armature voltage as an absolute value.
Dependency:
Refer to: r52292
Note:
100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi
r52292

CO: Armature voltage signed actual value / Ua act signed

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the signed actual value of the armature voltage.
Dependency:
Refer to: r52291
Note:
100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi
r52293
CO: EMF controller pre-control output / EMF ctr prec outp
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for pre-control on the EMF controller.
592
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 6900
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6830, 6835,
6851, 6910
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6902
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6902
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
- [%]