Co/Bo: Status Word, Closed-Loop Control / Zsw Cl-Loop Ctrl; Co: Speed Setpoint Before The Setpoint Filter / N_Set Before Filt.; Co: Actual Speed Unsmoothed / N_Act Unsmoothed; Co: Speed Actual Value / N_Act - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r0056.13

CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned16
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Display and BICO output for the status word of the closed-loop control.
Bit field:
Bit
13
r0060

CO: Speed setpoint before the setpoint filter / n_set before filt.

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [rpm]
Description:
Displays the actual speed setpoint at the speed controller input.
Dependency:
Refer to: r0020
Note:
The speed setpoint is available smoothed (r0020) and unsmoothed (r0060).
r0061[0...1]

CO: Actual speed unsmoothed / n_act unsmoothed

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
DC_CTRL_S
P-Group: Displays, signals
Not for motor type: -
Min
- [rpm]
Description:
Displays the unsmoothed actual speed values sensed by the encoders.
Index:
[0] = Encoder 1
[1] = Encoder 2
r0063[0...1]

CO: Speed actual value / n_act

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [rpm]
Description:
Displays the actual speed actual value for speed control.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Refer to: r0021, r0022, p0045, r0061
Note:
The speed actual value is available smoothed (r0021 with 100 ms, r0022 with 100 ms, r0063 with p0045) and
unsmoothed (r0063[0], r0061).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Current/torque limiting
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Active
Calculated: -
Dyn. index: -
Unit group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: -
Unit group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: -
Unit group: 3_1
Scaling: p2000
Max
- [rpm]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2526
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Inactive
Access level: 3
Func. diagram: 3155
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 2
Func. diagram: 1580, 4710,
6810
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 3
Func. diagram: 6810
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
FP
6060
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents