Co: Setpoint Processing Main Setpoint Lim Neg Default 0; Co: Setpoint Processing Main Setpoint Lim Neg Default 1; Co: Setpoint Processing Main Setpoint Lim Neg Default 2; Co: Setpoint Processing Main Setpoint Lim Neg Default 3 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52184
CO: Setpoint processing main setpoint lim neg default 0 / M set neg def 0
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the default value of variable negative main setpoint limiting with index 0.
Dependency:
Refer to: p50642
Note:
The value represents the inversion of p50642[0].
r52185
CO: Setpoint processing main setpoint lim neg default 1 / M set neg def 1
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the default value of variable negative main setpoint limiting with index 1.
Dependency:
Refer to: p50642
Note:
The value represents the inversion of p50642[1].
r52186
CO: Setpoint processing main setpoint lim neg default 2 / M set neg def 2
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the default value of variable negative main setpoint limiting with index 2.
Dependency:
Refer to: p50642
Note:
The value represents the inversion of p50642[2].
r52187
CO: Setpoint processing main setpoint lim neg default 3 / M set neg def 3
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the default value of variable negative main setpoint limiting with index 3.
Dependency:
Refer to: p50642
Note:
The value represents the inversion of p50642[3].
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]