Co: Line Analysis Armature Line Zero Crossing Positive Phase Wu; Co: Line Analysis Armature Line Zero Crossing Negative Phase Wu; Co: Line Analysis Field Line Zero Crossing Positive Phase F; Co: Line Analysis Field Line Zero Crossing Negative Phase F - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r52974
CO: Line analysis armature line zero crossing positive phase WU / Arm zero pos WU
DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the point in time (timer value) of the last positive zero crossing of armature phase WU.
Note:
The value is displayed in [10 ns] unit.
r52975
CO: Line analysis armature line zero crossing negative phase WU / Arm zero neg WU
DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the point in time (timer value) of the last negative zero crossing of armature phase WU.
Note:
The value is displayed in [10 ns] unit.
r52976
CO: Line analysis field line zero crossing positive phase F / Field zero pos F
DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the point in time (timer value) of the last positive zero crossing of the field phase.
Note:
The value is displayed in [10 ns] unit.
r52977
CO: Line analysis field line zero crossing negative phase F / Field zero neg F
DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the point in time (timer value) of the last negative zero crossing of the field phase.
Note:
The value is displayed in [10 ns] unit.
r52980
Cause of the armature firing pulse / Cause arm fir plus
DC_CTRL
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the cause of the armature firing pulse.
1: firing angle = firing angle specified by the armature current control (after Alpha G/W limiting).
2: firing angle = Alpha-W (= p50151, as Ia <> 0 or Ia = 0 for less than 125 µs).
3: firing angle = Alpha-W (= 165 °, as Ia = 0 for more than 125 µs).
628
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 4
Func. diagram: 6950
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 6950
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 6952
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 6952
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 8054
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM