2 Parameters
2.2 List of parameters
Note:
1 signal:
Analog input is enabled
0 signal:
Analog input is disabled (value = 0%)
p50727

CUD analog input 2 simulation setpoint / CUD AI 2 sim setp

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-130.0 [%]
Description:
Sets the setpoint for the simulation of analog input 2 (X177.29/30) on the CUD.
Dependency:
Refer to: p50729
Note:
Simulation is selected using p50729 = 1.
p50729

CUD analog input 2 simulation selection / CUD AI 2 sim sel

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to select the simulation of analog input 2 (X177.29/30) on the CUD.
Value:
0:
1:
Dependency:
Refer to: p50727
Note:
The setpoint for the simulation is set in p50727.
p50731[0...3]

Fast analog inputs scaling / Fast AI scal

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-1000.0 [%]
Description:
Sets the scaling for fast analog inputs "Select input 3 to 6".
The value indicates the percentage value for the mapping of an input voltage of 10 V at the analog input.
Example:
p50731[2] = 90%
--> 10 V is scaled to 90% for select input 5
--> 5 V corresponds to 45% for select input 5
Index:
[0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Note:
AI: Analog Input
506
Simulation deactivated
Simulation activated
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
130.0 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
1000.0 [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
0.0 [%]
Access level: 2
Func. diagram: 2080
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2085, 2090
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]