Trace Trigger Delay / Trace Trig_Delay; Trace Time Slice Cycle / Trace Cycle; Trace Average In The Time Range / Trace Average; Trace Data Type 1 Traced / Trace Rec Type 1 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p4722[0...1]

Trace trigger delay / Trace trig_delay

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
-3600000.000 [ms]
Description:
Sets the trigger delay for the trace.
Trigger delay < 0:
Pretrigger: Tracing (recording) starts the selected time before the trigger event actually occurs.
Trigger delay > 0:
Post trigger: Tracing does not start until the set time after the trigger event.
Index:
[0] = Trace 0
[1] = Trace 1
p4723[0...1]

Trace time slice cycle / Trace cycle

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0.03125 [ms]
Description:
Sets the time slice cycle in which the trace is called.
Index:
[0] = Trace 0
[1] = Trace 1
p4724[0...1]

Trace average in the time range / Trace average

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned8
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0000 bin
Description:
Sets the averaging in the time range for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
r4725[0...1]

Trace data type 1 traced / Trace rec type 1

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Displays the recorded data type 1 for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3600000.000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4.00000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
0001 bin
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0.000 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0.12500 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
261

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents