Co: Ramp-Function Generator Braking Distance (Floatingpoint32); Co: Temperature Sensor Display / Temp Sensor Disp; Co: Motor Temperature Output / Mot Temp Outp - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52048
CO: Ramp-function generator braking distance (FloatingPoint32) / RFG br dist float
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the braking distance required as increments of the pulse encoder defined in p0400.
The pulse encoder to be used must be selected using p50331.
The required braking distance is calculated assuming that the speed setpoint at the ramp-function generator input
has been set to 0 and the speed actual value is approaching 0, taking the set ramp-down time and roundings into
consideration.
Note:
For p0400[p50331] = 0, a braking distance of 0 is displayed.
The braking distance calculation is only correct if the ramp-down time and the roundings do not change during
braking (p50302, r00899.5, p50637, p50638).
r52049
Temperature sensor available / Temp_sens avail
DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the integrated temperature sensors.
Bit field:
Bit
00
01
02
03
Note:
The display is independent of the temperature sensor status and only indicates the desired state.
r52050[0...4]

CO: Temperature sensor display / Temp sensor disp

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the device's temperature outputs.
Index:
[0] = Temperature 1
[1] = Temperature 2
[2] = Temperature 3
[3] = Gating module temperature
[4] = CUD Control Unit temperature
Note:
Temperature sensors which are not in use return a high negative value (approx. -200 °C).
r52051

CO: Motor temperature output / Mot temp outp

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the motor temperature.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Temperature sensor XT5
Temperature sensor XT6
Temperature sensor XT7
Gating module temperature sensor
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Available
Available
Available
Available
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 3152
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 6960
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Not present
Not present
Not present
Not present
Access level: 1
Func. diagram: 8047, 8048
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 8030
Unit selection: -
Expert list: 1
Factory setting
- [%]
FP
6960
6960
6960
6960
565