pxxxx[0...n]

Parameter number

The parameter number is made up of a "p" or "r", followed by the parameter number and the
index (optional).
Examples of the representation in the parameter list:
• p...
• r...
• p0918
• p0099[0...3]
• p1001[0...n]
• r0944
• r2129.0...15
Other examples of the notation used in the documentation:
• p1070[1]
• p2098[1].3
• r0945[2](3)
• p0795.4
The following applies to adjustable parameters:
The parameter value "when shipped" is specified under "Factory setting" with the relevant unit
in square parentheses. The value can be adjusted within the range defined by "Min" and "Max".
The term "linked parameterization" is used in cases where changes to adjustable parameters
affect the settings of other parameters.
Linked parameterization can occur, for example, as a result of the following actions and
parameters:
• Executing macros
• Setting a PROFIBUS telegram (BICO interconnection)
• Setting component lists
• Automatically calculating and preassigning
• Restoring factory settings
The following applies to display parameters:
The fields "Min", "Max" and "Factory setting" are specified with a dash "-" and the relevant unit
in square parentheses.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Adjustable parameters (read and write parameters)
Display parameters (read only)
Adjustable parameter 918
Adjustable parameter 99, indices 0 to 3
Adjustable parameter 1001, indices 0 to n (n = configurable)
Display parameter 944
Display parameter 2129 with bit field from bit 0 (smallest bit) to bit 15
(largest bit)
Adjustable parameter 1070, index 1
Adjustable parameter 2098, index 1 bit 3
Display parameter 945, index 2 of drive object 3
Adjustable parameter 795, bit 4
p0015, p0700, p1000, p1500
p0922
p0400
p0112, p0340, p3900
p0970
2 Parameters
2.1 Overview of parameters
15