p50469[0...n]

Motorized potentiometer minimum speed / MotP n_min

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the minimum speed on the motorized potentiometer.
Dependency:
Refer to: p50471
Note:
This parameter is only effective in manual mode (p50471 = 0).
The setpoint output from the motorized potentiometer is limited to this value.
p50470[0...n]
BI: Motorized potentiometer signal source for CW/CCW / MotP CW/CCW sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for changing over between clockwise/counter-clockwise rotation on the motorized
potentiometer.
p50471[0...n]
BI: Motorized potentiometer signal source for manual/automatic / MotP man/aut sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for changing between manual and automatic modes.
Dependency:
Refer to: p50461, p50673, p50674
Note:
If p50471 = 0 signal (manual mode):
In manual mode, the setpoint is increased and reduced using binector inputs p50673 and p50674 respectively.
If p50471 = 1 signal (automatic mode):
In automatic mode, the setpoint is specified using connector input p50461.
p50472[0...n]

BI: Motorized potentiometer accept setting value / MotP acc set val

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source to accept the setting value for the motorized potentiometer.
Dependency:
Refer to: p50466
Note:
The setting value (CI: p50466) becomes effective on a 0/1 edge of the setting command (BI: p50472).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
-100.00 [%]
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0
463