Rfg Ramp-Up Time 2 / Rfg T_Ramp-Up 2; Rfg Ramp-Down Time 2 / Rfg Ramp-Dn Time 2; Rfg Initial Rounding 2 / Rfg Init Rndg 2; Rfg Final Rounding 2 / Rfg Fin Rndg 2 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p50307[0...n]

RFG ramp-up time 2 / RFG t_ramp-up 2

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the ramp-up time for ramp-function generator parameter set 2.
p50308[0...n]

RFG ramp-down time 2 / RFG ramp-dn time 2

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the ramp-down time for ramp-function generator parameter set 2.
p50309[0...n]

RFG initial rounding 2 / RFG init rndg 2

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the initial rounding for ramp-function generator parameter set 2.
Dependency:
Refer to: p50295
p50310[0...n]

RFG final rounding 2 / RFG fin rndg 2

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the final rounding for ramp-function generator parameter set 2.
Dependency:
Refer to: p50295
p50311[0...n]
RFG ramp-up time 3 / RFG t_ramp-up 3
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [s]
Description:
Sets the ramp-up time for ramp-function generator parameter set 3.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
650.00 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
650.00 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
100.00 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
100.00 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
650.00 [s]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
Access level: 2
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
Access level: 2
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
0.00 [s]
Access level: 2
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
0.00 [s]
Access level: 2
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
439

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents