2 Parameters
2.2 List of parameters
p50258[0...n]
Cl-loop field current control field current reduction delay time / If_ctr I_red t_del
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [s]
Description:
Sets the delay time for automatic field current reduction.
p50260[0...n]
Field current pre-control setpoint smoothing time constant / Field_prec set T
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the smoothing time constant for the setpoint for field current pre-control.
Dependency:
Refer to: p50261
Note:
This smoothing enables field-current pre-control to be decoupled from the field current controller.
p50261[0...n]
Field current controller setpoint smoothing time constant / I_field_ctr set T
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the smoothing time constant for the setpoint for the field current controller.
Dependency:
Refer to: p50260
Note:
This smoothing enables field-current pre-control to be decoupled from the field current controller.
p50263[0...n]

Selection of motor flux input variable / Mot fl input sel

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Selection of the input variable for determining the motor flux.
Value:
0:
1:
2:
Note:
If value = 0:
This setting is recommended for a fully compensated DC motor.
If value = 1:
This setting is recommended for an uncompensated DC motor. The EMF controller must be active for this setting (the
EMF controller compensates the armature reaction).
If value = 2:
This setting is recommended for a fully compensated DC motor.
430
Field current controller actual value (r52265)
EMF pre-control output (r52293 or r52268)
Field current controller setpoint (r52268)
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
60.0 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
2
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
10.0 [s]
Access level: 2
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 6910
Unit selection: -
Expert list: 1
Factory setting
1