Technology Controller Upper Limit Actual Value / Tec_Ctrl U_Lim Act; Technology Controller Lower Limit Actual Value / Tec_Ctrl L_Lim Act - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p2265
Technology controller actual value filter time constant / Tec_ctrl act T
DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
0.000 [s]
Description:
Sets the time constant for the actual value filter (PT1) of the technology controller.
r2266
CO: Technology controller actual value after filter / Tec_ctr act aftFlt
DC_CTRL (Tech_ctrl),
Can be changed: -
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
- [%]
Description:
Display and connector output for the smoothed actual value after the filter (PT1) of the technology controller.
p2267

Technology controller upper limit actual value / Tec_ctrl u_lim act

DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-200.00 [%]
Description:
Sets the upper limit for the actual value signal of the technology controller.
Dependency:
Refer to: p2252, p2264, p2265, p2271
Notice:
If the actual value exceeds this upper limit, this results in fault F07426.
Note:
Limiting only active for p2252.3 = 1.
p2268

Technology controller lower limit actual value / Tec_ctrl l_lim act

DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-200.00 [%]
Description:
Sets the lower limit for the actual value signal of the technology controller.
Dependency:
Refer to: p2264, p2265, p2271
Notice:
If the actual value falls below this lower limit, this results in fault F07426.
Note:
Limiting only active for p2252.3 = 1.
p2269
Technology controller gain actual value / Tech_ctrl gain act
DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
0.00 [%]
Description:
Sets the scaling factor for the actual value of the technology controller.
Dependency:
Refer to: p2264, p2265, p2267, p2268, p2271
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
60.000 [s]
Calculated: -
Dyn. index: -
Unit group: 9_1
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: -
Unit group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
500.00 [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0.000 [s]
Access level: 2
Func. diagram: 7958
Unit selection: p0595
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 7958
Unit selection: p0595
Expert list: 1
Factory setting
200.00 [%]
Access level: 3
Func. diagram: 7958
Unit selection: p0595
Expert list: 1
Factory setting
-200.00 [%]
Access level: 3
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
185