Bi: Signal Source To Enable Fast Analog Inputs / Fast Ai Ena Sig S; Fast Analog Inputs Setpoint Simulation / Fast Ai Sim Setp; Fast Analog Inputs Simulation Selection / Fast Ai Sim Sel - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Index:
[0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
p50736[0...3]

BI: Signal source to enable fast analog inputs / Fast AI ena sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for enabling fast analog inputs "Select input 3 to 6".
Index:
[0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Note:
1 signal:
Analog input is enabled
0 signal:
Analog input is disabled (value = 0%)
p50737[0...3]

Fast analog inputs setpoint simulation / Fast AI sim setp

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-130.0 [%]
Description:
Sets the setpoint for the simulation of the fast analog inputs (select input 3 ... 6).
Index:
[0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Dependency:
Refer to: p50739
Note:
Simulation is selected using p50739[0...3] = 1.
p50739[0...3]

Fast analog inputs simulation selection / Fast AI sim sel

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to select the simulation of the fast analog inputs (select input 3 ... 6).
Value:
0:
1:
Index:
[0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Dependency:
Refer to: p50737
Note:
The setpoint for the simulation is set in p50737[0...3].
508
Simulation deactivated
Simulation activated
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
130.0 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 2085, 2090
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 2085, 2090
Unit selection: -
Expert list: 1
Factory setting
0.0 [%]
Access level: 2
Func. diagram: 2085, 2090
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents