p51805

Parallel interface bus terminator / Par IF bus term

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to activate/de-activate the bus terminator on the parallel interface.
Value:
0:
1:
Dependency:
Refer to: p51806
p51806

Parallel interface bus address / Par IF bus addr

DC_CTRL
Can be changed: T
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
1
Description:
Sets the bus address for the parallel connection of devices.
Dependency:
Refer to: p51805
p51807
Parallel interface telegram monitoring failure time / Telegr mon t_fail
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.000 [s]
Description:
Sets the permissible telegram failure time for the parallel interface.
This setting means that every device connected to the parallel switching interface can monitor whether it is
connected to the parallel switching interface.
If a telegram is not received from any other device connected to the parallel switching interface for longer than the set
time, then BICO output r53310.0 is set to 1, and also fault F60014 is initiated in the factory setting.
Value = 0.0:
Telegram monitoring is de-activated.
Value = 0.001 ... 65.000:
Telegram monitoring is activated.
Dependency:
Refer to: p50099, r53310
Refer to: F60014
Note:
Telegram monitoring is active in the following cases:
- From the first error-free telegram received after the electronic power supply has been switched on The telegram can
be received from any device.
- From the first telegram received error-free after the telegram monitoring has responded (as a result of the failure
time expiring).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Bus terminator OFF
Bus terminator ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65.000 [s]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 9350
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 9350
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 9350
Unit selection: -
Expert list: 1
Factory setting
0.100 [s]