Connector/Binector Outputs (Co/Bo) - Siemens SINAMICS G120 List Manual

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

r20286
r20309
r20373
r20379
2.4.5

Connector/binector outputs (CO/BO)

Product: SINAMICS G120 CU240, Version: 4707900, Language: eng, Type: CO/BO
r0046.0...31
r0050.0...1
r0051.0...1
r0052.0...15
r0053.0...11
r0054.0...15
r0055.0...15
r0056.0...15
r0056.0...13
r0722.0...11
r0722.0...12
r0723.0...11
r0723.0...12
r0835.2...8
r0836.0...1
r0837.0...1
r0863.0...1
r0898.0...14
r0899.0...13
r1099.0
r1198.0...15
r1199.0...8
r1204.0...13
r1205.0...15
r1214.0...15
r1239.8...13
r1406.4...15
r1407.0...27
r1408.0...14
r1838.0...15
r2129.0...15
r2135.12...15
r2138.7...15
r2139.0...15
r2197.0...13
r2198.0...13
r2199.0...11
r2225.0
r2349.0...13
r3113.0...15
r3333.0...3
r3840.0...8
r3859.0
r5389.0...8
r5613.0...1
r7760.0...12
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
CO: DIF 0 output Y / DIF 0 output Y
CO: ADD 2 output Y / ADD 2 output Y
CO: PLI 0 output Y / PLI 0 output Y
CO: PLI 1 output Y / PLI 1 output Y
CO/BO: Missing enable sig / Missing enable sig
CO/BO: Command Data Set CDS effective / CDS effective
CO/BO: Drive Data Set DDS effective / DDS effective
CO/BO: Status word 1 / ZSW 1
CO/BO: Status word 2 / ZSW 2
CO/BO: Control word 1 / STW 1
CO/BO: Supplementary control word / Suppl STW
CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
CO/BO: CU digital inputs status / CU DI status
CO/BO: CU digital inputs status / CU DI status
CO/BO: CU digital inputs status inverted / CU DI status inv
CO/BO: CU digital inputs status inverted / CU DI status inv
CO/BO: Data set changeover status word / DDS_ZSW
CO/BO: Command Data Set CDS selected / CDS selected
CO/BO: Drive Data Set DDS selected / DDS selected
CO/BO: Drive coupling status word/control word / CoupleZSW/STW
CO/BO: Control word sequence control / STW seq_ctrl
CO/BO: Status word sequence control / ZSW seq_ctrl
CO/BO: Skip band status word / Skip band ZSW
CO/BO: Control word setpoint channel / STW setpoint chan
CO/BO: Ramp-function generator status word / RFG ZSW
CO/BO: Flying restart U/f control status / FlyRest Uf st
CO/BO: Flying restart vector control status / FlyRest vector st
CO/BO: Automatic restart status / AR status
CO/BO: DC braking status word / DCBRK ZSW
CO/BO: Control word speed controller / STW n_ctrl
CO/BO: Status word speed controller / ZSW n_ctrl
CO/BO: Status word current controller / ZSW I_ctrl
CO/BO: Gating unit status word 1 / Gating unit ZSW1
CO/BO: Faults/alarms trigger word / F/A trigger word
CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
CO/BO: Control word faults/alarms / STW fault/alarm
CO/BO: Status word faults/alarms 1 / ZSW fault/alarm 1
CO/BO: Status word monitoring 1 / ZSW monitor 1
CO/BO: Status word monitoring 2 / ZSW monitor 2
CO/BO: Status word monitoring 3 / ZSW monitor 3
CO/BO: Technology controller fixed value selection status word / Tec_ctr FixVal ZSW
CO/BO: Technology controller status word / Tec_ctrl status
CO/BO: NAMUR message bit bar / NAMUR bit bar
CO/BO: 2/3 wire control control word / 2/3 wire STW
CO/BO: Friction characteristic status word / Friction ZSW
CO/BO: Compound braking/DC quantity control status word / Comp-br/DC_ctr ZSW
CO/BO: Mot_temp status word faults/alarms / Mot_temp ZSW F/A
CO/BO: Pe energy-saving active/inactive / Pe save act/inact
CO/BO: Write protection/know-how protection status / Wr_prot/KHP stat
2.4 BICO parameters (connectors/binectors)
2 Parameters
549