Connector/Binector (Bico)-Parameters; Binector Input Parameters - Siemens SINAMICS G120 Manual

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Parameters

Connector/Binector (BICO)-Parameters

1.4
Connector/Binector (BICO)-Parameters
1.4.1

Binector Input Parameters

Product: SINAMICS G120, Version: 4402100, Language: eng, Type: BI
p0730
p0731
p0732
p0782[0...1]
p0806
p0810
p0811
p0820[0...n]
p0821[0...n]
p0840[0...n]
p0844[0...n]
p0845[0...n]
p0848[0...n]
p0849[0...n]
p0852[0...n]
p0854[0...n]
p1020[0...n]
p1021[0...n]
p1022[0...n]
p1023[0...n]
p1035[0...n]
p1036[0...n]
p1039[0...n]
p1041[0...n]
p1043[0...n]
p1055[0...n]
p1056[0...n]
p1108[0...n]
p1110[0...n]
p1111[0...n]
p1113[0...n]
p1122[0...n]
p1140[0...n]
p1141[0...n]
p1142[0...n]
p1143[0...n]
p1201[0...n]
p1230[0...n]
p1266
p1269[0...1]
p1476[0...n]
p1477[0...n]
p1492[0...n]
p1501[0...n]
p2080[0...15]
p2081[0...15]
1-480
BI: CU signal source for terminal DO 0 / CU S_src DO 0
BI: CU signal source for terminal DO 1 / CU S_src DO 1
BI: CU signal source for terminal DO 2 / CU S_src DO 2
BI: CU analog outputs invert signal source / CU AO inv S_src
BI: Inhibit master control / PcCtrl inhibit
BI: Command data set selection CDS bit 0 / CDS select., bit 0
BI: Command data set selection CDS bit 1 / CDS select., bit 1
BI: Drive Data Set selection DDS bit 0 / DDS select., bit 0
BI: Drive Data Set selection DDS bit 1 / DDS select., bit 1
BI: ON / OFF (OFF1) / ON / OFF (OFF1)
BI: No coast-down / coast-down (OFF2) signal source 1 / OFF2 S_src 1
BI: No coast-down / coast-down (OFF2) signal source 2 / OFF2 S_src 2
BI: No Quick Stop / Quick Stop (OFF3) signal source 1 / OFF3 S_src 1
BI: No Quick Stop / Quick Stop (OFF3) signal source 2 / OFF3 S_src 2
BI: Enable operation/inhibit operation / Operation enable
BI: Control by PLC/no control by PLC / Master ctrl by PLC
BI: Fixed speed setpoint selection Bit 0 / n_set_fixed Bit 0
BI: Fixed speed setpoint selection Bit 1 / n_set_fixed Bit 1
BI: Fixed speed setpoint selection Bit 2 / n_set_fixed Bit 2
BI: Fixed speed setpoint selection Bit 3 / n_set_fixed Bit 3
BI: Motorized potentiometer setpoint raise / Mop raise
BI: Motorized potentiometer lower setpoint / Mop lower
BI: Motorized potentiometer inversion / MotP inv
BI: Motorized potentiometer manual/automatic / Mop manual/auto
BI: Motorized potentiometer accept setting value / MotP acc set val
BI: Jog bit 0 / Jog bit 0
BI: Jog bit 1 / Jog bit 1
BI: Total setpoint selection / Total setp sel
BI: Inhibit negative direction / Inhib neg dir
BI: Inhibit positive direction / Inhib pos dir
BI: Setpoint inversion / Setp inv
BI: Bypass ramp-function generator / Bypass RFG
BI: Enable ramp-function generator/inhibit ramp-function generator / RFG enable
BI: Continue ramp-function generator/freeze ramp-function generator / Continue RFG
BI: Enable setpoint/inhibit setpoint / Setpoint enable
BI: Ramp-function generator, accept setting value / RFG accept set v
BI: Flying restart enable signal source / Fly_res enab S_src
BI: DC braking activation / DC brake act
BI: Bypass, control command / Bypass command
BI: Bypass switch feedback signal / Bypass FS
BI: Speed controller hold integrator / n_ctrl integ stop
BI: Speed controller set integrator value / n_ctrl integ set
BI: Droop feedback enable / Droop enable
BI: Change over between closed-loop speed/torque control / Changeov n/M_ctrl
BI: Binector-connector converter status word 1 / Bin/con ZSW1
BI: Binector-connector converter status word 2 / Bin/con ZSW2
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
© Siemens AG 2011 All Rights Reserved