Connector/Binector Output Parameters - Siemens Sinamics G120 Series Parameter Manual

Hide thumbs Also See for Sinamics G120 Series:
Table of Contents

Advertisement

Parameters
Connector/Binector (BICO)-Parameters
r2245
r2250
r2260
r2262
r2266
r2272
r2273
r2294
r2477
r2478
r2489[0...2]
r2870
r2872
r2874
r2876
r2878
r2880
r2882
r2884
p2889
p2890
r2955
r8850[0...7]
r9660
1.4.5

Connector/Binector Output Parameters

r0019.0...14
r0050
r0052.0...15
r0053.0...15
r0054.0...15
r0055.0...15
r0056.0...15
r0403.0...4
r0722.0...12
r0747.0...2
r0751.0...9
r0785.0...1
r1407.0...15
r1751.0...15
r2197.0...12
r2198.0...12
r3113.0...15
r9771.0...1
r9772.0...15
1-312
CO: PID-MOP input frequency of the RFG / PMOP RFG input
CO: Output setpoint of PID-MOP / PMOP outp. setp
CO: PID setpoint after PID-RFG / PID setp <-RFG
CO: Filtered PID setp. after RFG / Filt. PID setp
CO: PID filtered feedback / PID filt.fdbck
CO: PID scaled feedback / PID scal fdbck
CO: PID error / PID error
CO: Act. PID output / Act.PID output
CO: Act. scaled encoder speed / Act scal enc speed
CO: Act. scaled encoder frequency / Act scal enc freq
CO: Tracking parameter / Track / Tracking parameter
CO: ADD 1 / ADD 1
CO: ADD 2 / ADD 2
CO: SUB 1 / SUB 1
CO: SUB 2 / SUB 2
CO: MUL 1 / MUL 1
CO: MUL 2 / MUL 2
CO: DIV 1 / DIV 1
CO: DIV 2 / DIV 2
CO: Fixed setpoint 1 in [%] / Fixed setp 1 %
CO: Fixed setpoint 2 in [%] / Fixed setp 2 %
CO: Wobble signal output / Wobble output
CO: PZD from Fieldbus / PZD from FB
CO: SI remain time until forc dynam / SI remaining time
CO/BO: BOP control word / BOP CtrlWd
CO/BO: Active Command Dataset / Active CDS
CO/BO: Act. status word 1 / Act StatWd1
CO/BO: Act. status word 2 / Act StatWd2
CO/BO: Act. control word 1 / Act CtrlWd1
CO/BO: Act. control word 2 / Act CtrlWd2
CO/BO: Status of motor control / CO/BO:Stat MotCtrl
CO/BO: Encoder status word / Enc. StatWd
CO/BO: Binary input values / Bin.inp.val
CO/BO: State of digital outputs / CO/BO:State DOs
CO/BO: Status word of AI / AI status Wd
CO/BO: Status word of AO / AO stat Wd
CO/BO: Status 2 of motor control / Stat 2 ctrl
CO/BO: Status word of motor model / Motor model StatWd
CO/BO: Monitoring word 1 / Monitor Wd1
CO/BO: Monitoring word 2 / Monitor Wd2
CO/BO: Fault Bit Array / Fault Bit Array
CO/BO: SI hardware functions / SI hw functions
CO/BO: SI status word / SI StatWd
© Siemens AG 2007 All Rights Reserved