29.11
Adjusting the circular
level step-by-step

Adjusting the Circular Level of the Prism Pole

4b
1
2
4a
TPS12_232
Step
Description
1.
Suspend a plumb line.
2.
Using a pole bipod, align the prism pole parallel to the plumb line.
3.
Check the position of the circular level on the prism pole.
4.
a) If the circular level is centered, no adjustment is necessary.
b) If the circular level is not centered, use an allen key to centre it with the adjust-
ment screws.
After the adjustments, all adjusting screws should have the same tightening