F07475 (A)
EPOS: Target position < start of traversing range
Message value:
-
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Drive object:
VECTOR_G
Reaction:
OFF1 (OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The target position for relative traversing lies outside the traversing range.
Remedy:
Correct the target position.
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F07476 (A)
EPOS: Target position > end of the traversing range
Message value:
-
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Drive object:
VECTOR_G
Reaction:
OFF1 (OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The target position for relative traversing lies outside the traversing range.
Remedy:
Correct the target position.
Reaction upon A:
NONE
Acknowl. upon A:
NONE
A07477 (F)
EPOS: Target position < software limit switch minus
Message value:
-
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Drive object:
VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
In the actual traversing operation, the target position is less than the software limit switch minus.
Remedy:
- correct the target position.
- change software limit switch minus (CI: p2578, p2580).
Reaction upon F:
OFF1 (OFF2, OFF3)
Acknowl. upon F:
IMMEDIATELY
A07478 (F)
EPOS: Target position > software limit switch plus
Message value:
-
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Drive object:
VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
In the actual traversing operation, the target position is greater than the software limit switch plus.
Remedy:
- correct the target position.
- change software limit switch plus (CI: p2579, p2581).
Reaction upon F:
OFF1 (OFF2, OFF3)
Acknowl. upon F:
IMMEDIATELY
A07479
EPOS: Software limit switch minus reached
Message value:
-
Message class:
Application / technological function faulted (17)
Drive object:
VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
The axis is at the position of the software limit switch minus. An active traversing block was interrupted.
Remedy:
- correct the target position.
- change software limit switch minus (CI: p2578, p2580).
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
4 Faults and alarms
4.2 List of faults and alarms