Hydraulic Pressure Circuit When Abs Is Not Operating; No Hydraulic Pressure Circuit When Abs Is Operating - SSANGYONG 2004 Rexton 2.7XDi Workshop Manual

Table of Contents

Advertisement

8E1-12
ABS HYDRAULIC CIRCUIT PER ABS OPERATION RANGE

Hydraulic Pressure Circuit when ABS is Not Operating

The hydraulic pressure in the master cylinder increases through the vacuum booster and it is delivered to the wheel via
the normal open inlet valve. At this moment, the normally-closed outlet valve is closed. The speed of the wheel that
hydraulic pressure is delivered reduces gradually .

No Hydraulic Pressure Circuit when ABS is Operating

Low pressure
chamber
Pump
As hydraulic pressure on each wheel increases, the wheel tends to lock. In order to prevent the wheel from locking, the
hydraulic valve modulator operates the inlet valve control solenoid to close the inlet valve and stop the hydraulic pressure
increases. At this moment, the outlet valve is closed. This procedure helps the wheel to maintain a stable hydraulic
pressure.
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
Low pressure
chamber
Pump
Inlet valve
Outlet valve
Inlet valve
Outlet valve
Constant pressure
REXTON SM - 2004.4
Y220_8E1013
Y220_8E1014
ABS

Hide quick links:

Advertisement