10A-18
Trouble
Trouble Description
Code
52
Safety time exceeded
53
Flame aborted from "power" stage
54
Flame aborted from "large" stage
56
Flame aborted from "small" stage
60
Control overheating sensor interrup-
tion
61
Short circuit or ground contact con-
trol overheating sensor
64
Flame sensor interruption
65
Short circuit flame sensor
71
Surface sensor interruption
72
Short circuit surface sensor
74
Overheating hardware defect, operating
block
87
Internal temperature sensor short-circuit
88
Internal temperature sensor interruption
89
CAN error
90
Watch dog reset
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
• Check exhaust and combustion air system
• Check fuel quantity and fuel supply
• Clean or replace sieve used in fitting of fuel pump
Warning
In the case of flame aborted in "power", "large" and "small"
stage and with still tolerable start attempts, the heater proceeds
with a new start or with subsequent start repeat. If the new
start or start repeat is successful, the trouble code display goes
off.
Fault(because no more start attempt allowed )
• Check exhaust and combustion air system
• Check fuel quantity and fuel supply
• Check flame sensor - see trouble code 64 and 65
• Check cable harness to this component for damage and through
current
• Check plug-in connection
• Check sensor resistance value, replace component if necessary
• Check cable harness to this component for damage
• Check sensor resistance value, replace external component if
necessary
• Check cable harness to this component for damage and
through current
• Check plug-in connection
• Check sensor resistance value, replace component if necessary
• Check cable harness to this component for damage
• Check sensor resistance value, replace external component if
necessary
• Check cable harness to this component for damage and through
current
• Check plug-in connection
• Check sensor resistance value, replace component if necessary
• Check cable harness to this component for damage
• Check sensor resistance value, replace external component if
necessary
• Replace controller
• Replace controller
• Replace controller
• Check CAN interface
• Replace controller
Remedies