Check flame sensor
Specifiedl value
Temperature [ ° C]
0
Resistance [Ω]
1000
±10
Combustion air fan
FFH/PTC SYSTEM
REXTON SM - 2004.4
Y220_10A031
10
20
30
50
1022
1062
1097
1194
±10
±11
±11
±12
Y220_10A032
Y220_10A033
Check the surface sensor with a digital multimeter. If the re-
sistance of flame sensor is out of specified values, the flame
sensor is defective.
80
100
90
130
1309
1347
1385
1498
±13
±15
±14
±17
1. Combustion chamber
2. O-ring
3. Rubber seal
4. Combustion air fan
150
250
300
200
1573
1758
1941
2120
±20
±28
±32
±24
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
10A-23
400
350
2297
2470
±40
±36