Mode Controls Does Not Work - SSANGYONG 2004 Rexton 2.7XDi Workshop Manual

Table of Contents

Advertisement

10C-60

Mode Controls Does Not Work

Step
Measure the voltage between terminal 4 of the blower motor and mode
door motor ground.
1
Is the voltage within the specified value?
Repair the connector and the circuit for any wiring or terminal problems.
2
Is the repair complete?
1. Using the Motor Control Table, measure the voltages at the specified
terminals of the specified motor connectors.
3
2. Change the mode settings and observe the voltage changes.
Is the voltage within the specified value?
Repair or replace the wiring harness or the defective terminal.
4
Is the repair complete?
1. Measure the voltages of the connector terminal.
2. Change the mode settings and observe the voltage changes.
5
Is the voltage within the specified value?
6
Replace the fuel filter or the fuel line.
Check the connector at the controller.
7
Is there a defective terminal?
Repair the terminal and replace as needed.
8
Is the repair complete?
Replace the controller.
9
Is the repair complete?
Mode Controls Does Not Work
Step
Measure the voltage between terminal 4 of the intake control door motor
and ground.
1
Is the voltage within the specified value?
Repair the connector and the circuit for any wiring or terminal problems.
2
Is the repair complete?
1. Measure the voltages at the specified terminals of the specified motor
connectors.
3
2. Change the mode settings and observe the voltage changes
Is the voltage within the specified value?
1. Repair the wiring harness or the defective terminal.
2. Replace the fuel filter or the fuel line as needed.
4
Is the repair complete?
Check the connector at the controller.
5
Is there a defective terminal?
Repair the terminal and replace as needed.
6
Is the repair complete?
Replace the controller.
7
Is the repair complete?
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
Action
Action
Yes
No
Go to Step 3
11 ~ 14 V
Go to Step 2
System OK
-
Go to Step 5
Go to Step 4
System OK
-
Go to Step 7
Go to Step 6
System OK
-
Go to Step 8
Go to Step 9
System OK
-
System OK
-
Yes
No
Go to Step 3
11 ~ 14 V
Go to Step 2
System OK
-
Go to Step 5
Go to Step 4
System OK
-
Go to Step 6
Go to Step 7
System OK
-
System OK
-
A/C SYSTEM
REXTON SM - 2004.4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents