Symptom
1. The low-pressure side indicates excessive high
and high-pressure indicates excessive low.
2. There is a moisture in the connection of the re-
ceiver-drier and the front/back of the expansion
valve.
1. The low-side pressure is high or normal intermit-
tently.
1. The low-pressure and high-pressure are exces-
sive high.
2. There are a lot of moistures in the connection of
the low-side pressure
1. The low-pressure is excessive high and high-
pressure is excessive low.
A/C SYSTEM
REXTON SM - 2004.4
Cause
The dust and moisture
etc. are frozen at the
expansion valve
A gas leak in the heat
reducer
Y220_10C015
The mixed moisture is
frozen at the expansion
valve
Y220_10C016
The faulty expansion
valve, the improper
installation of the heat
reducer
Fail to control the flow
rate
Y220_10C017
There is an oil leak in
the compressor
Y220_10C018
10C-15
Action
Repair the receiver-drier
Replace the expansion
valve for the faulty heat
reducer
Repair the receiver-drier
and perform the bleeding
Repair the receiver-drier
Check the oil
contamination etc.
Replace the compressor