SSANGYONG 2004 Rexton 2.7XDi Workshop Manual page 1230

Table of Contents

Advertisement

8E2-32
If two signals from pressure sensor deviates from the specified value, HECU determines the sensor is faulty. The sensor
output is analog signal that is proportional to voltage and the HECU recognized the pressure value as signal value
against supplying voltage.
Maximum measurable pressure: 170 bar
Linear changes of about 0.5 volts when the brake is not operating and 4.75 volts when the brake is operating.
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
ESP SYSTEM
REXTON SM - 2004.4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents