When Applied Abs (Increased Pressure) - SSANGYONG 2004 Rexton 2.7XDi Workshop Manual

Table of Contents

Advertisement

(4) When applied ABS (increased pressure)

Low pressure
chamber
Pump
The shuttle valve and inlet valve will be open and the separation valve and outlet valve will be closed. Then, the pump is
operated.
When ESP operates while the ABS is operating, the pressure will be increased continuously until just before the
corresponding wheel gets locked.
ESP SYSTEM
REXTON SM - 2004.4
Shuttle valve
Inlet valve
Separation valve
Outlet valve