Ffh Unit - Removal And Installation - SSANGYONG 2004 Rexton 2.7XDi Workshop Manual

Table of Contents

Advertisement

FFH Unit - Removal and Installation

1. Open the engine hood.
2. Disconnect the FFH coolant circulation pump connector.
3. Unscrew the bracket nut for coolant circulation pump.
Tightening torque
4. Release the clamps and remove the inlet and outlet hoses
from coolant circulation pump.
Notice
• Be careful not to splash the coolant to engine,
painted surface and body.
• The coolant hose is delivered as an assembly and
the coolant hose bracket is installed to the
transmission. When removing the hose, slightly
lower the rear section of the transmission and pull
out it through the clearance between engine and
transmission.
FFH/PTC SYSTEM
REXTON SM - 2004.4
10 ± 1.0 Nm
10A-27
Y220_10A043
Y220_10A044
Y220_10A045
Y220_10A046
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN

Hide quick links: