r2067[0...1]
IF1 PZD maximum interconnected / IF1 PZDmaxIntercon
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Communications
CU_G150_DP,
Not for motor type: -
VECTOR_G, B_INF,
TM31, TM120, TM150,
Min
TB30, ENC
-
Description:
Display for the maximum interconnected PZD in the receive/send direction
Index 0: receive (r2050, r2060)
Index 1: send (p2051, p2061)
p2070
IF1 PROFIdrive SIC/SCC start receive / SIC/SCC start recv
VECTOR_G
Can be changed: T
Data type: Unsigned8
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the start for the SIC/SCC telegram (p60122) in the receive words (r2050, r2060).
Dependency:
Refer to: p0922, p2071, p2079, p60122
Note:
For setting p0922/p2079, the value is preset to the end of the PZD telegram.
For p0922 equal to 999 and p2079 not equal to 999, the preset value can be increased.
The value must be set again after changing p0922/p2079.
p2071
IF1 PROFIdrive SIC/SCC start send / SIC/SCC start send
VECTOR_G
Can be changed: T
Data type: Unsigned8
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the start for the SIC/SCC telegram (p60122) in the send words (p2051, p2061).
Dependency:
Refer to: p0922, p2079, p60122
Note:
For setting p0922/p2079, the value is preset to the end of the PZD telegram.
For p0922 equal to 999 and p2079 not equal to 999, the preset value can be increased.
The value must be set again after changing p0922/p2079.
p2072
Response receive value after PZD failure / Resp aft PZD fail
VECTOR_G
Can be changed: T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
-
Description:
Sets the response for the receive value (r2090) after PZD failure.
Bit field:
Bit
00
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Unconditionally open holding brake (p0855) Freeze value
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
29
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
30
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2423
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2423
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
Zero the value
FP
-
517