p0449[0...n]
Encoder SSI number of bits filler bits / Enc SSI fill bits
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the number of filler bits for double absolute value transfer in the SSI protocol.
Dependency:
Refer to: p0429
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
This parameter is only of significance for p0429.2 = 1.
r0451[0...2]
Commutation angle factor / Enc commut_factor
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the relationship between the electrical and mechanical pole positions.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Note:
A value of zero is displayed if an encoder is not present.
r0452[0...2]
Squarewave encoder filter time display / Enc t_filt displ
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Encoder
Not for motor type: -
Min
- [µs]
Description:
Displays the effective filter time for a squarewave encoder.
The filter time is set using p0438.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0438
Note:
A value of zero is displayed if an encoder is not present.
r0452
Squarewave encoder filter time display / Enc t_filt displ
ENC
Can be changed: -
Data type: FloatingPoint32
P-Group: Encoder
Not for motor type: -
Min
- [µs]
Description:
Displays the effective filter time for a squarewave encoder.
The filter time is set using p0438.
Dependency:
Refer to: p0438
Note:
A value of zero is displayed if an encoder is not present.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [µs]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [µs]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 4710
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [µs]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [µs]