For bit 06, 08:
These status bits are used for internal diagnostic purposes only.
For bit 12, 11:
These status bits are used for the classification of internal alarm classes and are intended for diagnostic purposes
only on certain automation systems with integrated SINAMICS functionality.
p2140[0...n]
Hysteresis speed 2 / n_hysteresis 2
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the hysteresis speed (bandwidth) for the following signals:
"|n_act| < = speed threshold value 2" (BO: r2197.1)
"|n_act| > speed threshold value 2" (BO: r2197.2)
Dependency:
Refer to: p2155, r2197
p2141[0...n]
Speed threshold 1 / n_thresh val 1
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the speed threshold value for the signal "f or n comparison value reached or exceeded" (BO: r2199.1).
Dependency:
Refer to: p2142, r2199
p2142[0...n]
Hysteresis speed 1 / n_hysteresis 1
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the hysteresis speed (bandwidth) for the signal "f or n / v comparison value reached or exceeded" (BO:
r2199.1).
Dependency:
Refer to: p2141, r2199
p2144[0...n]
BI: Motor stall monitoring enable (negated) / Mot stall enab neg
VECTOR_G
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the negated enable (0 = enable) of the motor stall monitoring.
Dependency:
Refer to: p2163, p2164, p2166, r2197, r2198
Refer to: F07900
Note:
When interconnecting the enable signal with r2197.7 then the stall signal is suppressed if there is no speed setpoint -
actual value deviation.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: -
Max
300.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: -
Max
300.00 [rpm]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
90.00 [rpm]
Access level: 3
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
5.00 [rpm]
Access level: 3
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
2.00 [rpm]
Access level: 3
Func. diagram: 8012
Unit selection: -
Expert list: 1
Factory setting
0
549