r1918[0...2]
Identified stator inductance 3 / L_stator 3 ident
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor identification
Not for motor type: -
Min
- [mH]
Description:
Displays the stator inductance identified for the 3rd point of the saturation characteristic.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
r1919[0...2]
Identified stator inductance 4 / L_stator 4 ident
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor identification
Not for motor type: -
Min
- [mH]
Description:
Displays the stator inductance identified for the 4th point of the saturation characteristic.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
r1920[0...2]
Identified dynamic leakage inductance / L_leak dyn ident
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor identification
Not for motor type: -
Min
- [mH]
Description:
Displays the identified dynamic total leakage inductance.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
r1921[0...2]
Identified dynamic leakage inductance 1 / L_leak 1 dyn id
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor identification
Not for motor type: -
Min
- [mH]
Description:
Displays the identified dynamic leakage inductance 1.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [mH]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [mH]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [mH]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [mH]
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mH]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mH]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mH]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mH]