Note:
SMI: SINAMICS Sensor Module Integrated
DQI: DRIVE-CLiQ Sensor Integrated
Help for error value = 11:
- Save the data for the original SMI on the memory card.
- Use an SMI with a suitable hardware version.
Help for error value = 12:
- set the correct component number or connect the component.
Help for error value = 13:
- Use a memory card with more memory space.
Help for error value = 14:
- Create a data backup on the memory card corresponding to the SMI type.
Help for error value = 15:
- check the DRIVE-CLiQ wiring for the component.
Help for error value = 16:
- check the DRIVE-CLiQ wiring for the component.
Help for error value = 17:
- Save the data for the original SMI on the memory card.
Help for error value = 18:
- set parameter p4693 to an appropriate value.
Help for error value = 19:
- Perform an SMI delete or use a blank SMI.
Help for error value = 20:
- Use an SMI that is not blank.
Help for error value = 21:
- set the correct component number (p4690).
Note for error value = 22:
- Data cannot be downloaded for component.
Help for error value = 35:
- Reset parameter p4691 to 30.
Help for error value = 37:
- set the access level to Expert or higher.
Help for error value = 38:
- insert the SMI/DQI into the actual topology as an additional component (component number >= 200).
- set the component number from the actual topology (p4690 >= 200).
- set the correct component number (p4690 >= 200).
Note for error value = 39:
- SMI already deleted or too old. Delete not possible.
p4692
SMI spare part save data of all SMIs / Save SMI data
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Displays, signals
CU_G150_DP
Not for motor type: -
Min
0
Description:
Setting to back up the data of all SMIs and DQIs featured in the target topology.
Value:
0:
1:
10:
13:
16:
20:
29:
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Inactive
Save data of all SMIs and DQIs
Save all data successful
Insufficient memory space for backup
Transfer fault during data backup
Component does not contain any data
Not all components from target topology saved
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
29
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
699